Welch Allyn HScribe Holter Analysis System Features
- Continuous 12-lead Holter analysis system configured for clinical research.
- Integrates with Surveyor systems for complete Holter analysis and ECG export.
- Export ECG waveform in XML format (FDA required) for selected time points.
- Identify subject data by protocol with database on PC or redundant server.
- Multiple workstations can acquire, review, and generate reports within a shared DB.
- Export 10-second, 12-lead ECG data to E-Scribe system for further analysis.
Specifications
Welch Allyn HScribe Holter Analysis System Specifications
- Workstation Minimum Specifications:
- Processor: Performance equivalent to an Intel Core i3.
- Graphics: 1280 x 1024 (1920 x 1080 recommended).
- RAM: 4 GB.
- Operating System: Microsoft Windows 7 Professional 32-bit or 64-bit; Microsoft Windows 8.1 Professional 64 bit; Microsoft Windows 10 Pro 64 bit.
- Hard Drive Capacity: 160 GB.
- Archive: Network or external USB drive.
- Input Devices: USB Standard keyboard and 2-button scroll mouse.
- Software Installation: CD-ROM.
- Network: 100 Mbps connection or better.
- Printing Devices:
- HP M604n Laser printer (tested).
- HP PCL5-compatible printer series (recommended).
- USB Ports: 2 free USB 2.0 ports.
- Server Minimum Specifications:
- Processor: Performance Equivalent to Intel Xeon class, Quad-Core with hyper-threading.
- Graphics: 1024 x 768.
- RAM: 4 GB.
- Operating System: Microsoft Windows 2008 or 2012 server R2, 64-bit.
- System Disk: 100 GB for OS and product installation (RAID recommended for data redundancy).
- Data Disks:
- 550 GB hard drive space available.
- HD controller with 128 MB read/write cache (RAID recommended for data redundancy).
- Archive: Network or external USB drive.
- Software Installation: CD-ROM.
- Network: 100 Mbps connection or better.
- Input Devices: Standard keyboard and mouse.
- Connectivity Interfaces:
- Orders:
- XML:
- Mortara XML.
- Accepts orders via XML files saved by external system in a shared folder.
- DICOM Modality Worklist: Able to retrieve Holter test orders from a DICOM Service Class Provider (SCP) by performing a DICOM Modality Worklist query.
- HL7: By adding optional Mortara HL7 Gateway.
- XML:
- DICOM Modality Worklist Query Parameters:
- Modality.
- Institution Name.
- Scheduled Station Name.
- Scheduled Procedure Step Location.
- Current Patient Location.
- Requested Procedure Location.
- Scheduled Procedure Step Description.
- Scheduled Station AE Title.
- Number of Days Before and After “Today”.
- Requested Procedure Description.
- Export Formats Supports exporting data in the following formats:
- PDF.
- XML.
- DICOM.
- HL7: By adding optional Mortara HL7 Gateway.
- Orders:
- Physical Characteristics:
- Operating Temperature: +10 degrees C to +35 degrees C (+50 degrees F to +95 degrees F).
- Storage Temperature: -40 degrees to +65 degrees C (-40 degrees to +149 degrees F).
- Operating/Storage Humidity: 8% to 80%, non-condensing.
- Altitude (Pressure): 3,000 meters.
Reviews