SUMMER SALE FOR ALL OUTDOOR PRODUCTS AND FREE EXPRESS DELIVERY

CASE Value ECG System

$15,000.00

Free shipping for orders over $200

Free gift wrapping

Related Products

Before Purchasing: This item can only be sold to Medical Doctors. The FDA requires a prescription for the purchase of this item.

Warranty: 1 Year.

The CASE System is a stand-alone, highly scalable exercise testing solution that helps physicians quickly and easily access cardiac function during exercise. Its exclusive ergonomic features include a backlit keyboard and well-lit printing surface for effortless and confident operation in rooms darkened for stress echo tests. A centrally mounted, full-size monitor swivels for comfortable viewing. A familiar, Windows XP-based interface minimizes the learning curve. And a flexible interface accommodates multiple custom set-ups.

With the GE CASE Exercise Testing System, clinicians can easily acquire, analyze, store, and transport resting ECG, exercise stress tests, ambulatory blood pressure and spirometry measurements using one system. The CASE’s streamlined workflow and digital connectivity help speed patient care and increase staff productivity. The CASE features an adjustable monitor for comfort and productivity, open system architecture, advanced security and compliance, and technical support services you can count on.

Connect your CASE System to a local area network (LAN), and you can store patient data and test results to a central database. This enables physicians to review, edit, and print data remotely, for maximum efficiency in your stress lab.

Features

GE CASE Value ECG System Features

  • Assess cardiac function conveniently during exercise.
  • Innovative algorithms offer great diagnostic confidence.
  • Connect your CASE system to a Local Area Network (LAN) and store patient data and test results to a central database.
  • Physicians can review, edit, and print data remotely.
  • Enhance your digital workflow with connectivity to EMR, MUSE Cardiology Information System, and PACS.
  • Advanced security and compliance.
  • Productivity tools help to speed processes, reduce data entry errors, download orders, and support efficient change capture.
  • Access cardiac function conveniently during exercise.

Specifications

GE CASE Value ECG System Specifications

  • ECG Analysis Frequency: 500 Hz.
  • ST Measurements: ST amplitudes, slope, integral, index, ST/HR slope, ST/HR loops, ST/HR index up to 15 leads.
  • E, J, and Post-J Point: Manual or computer selected.
  • Signal Processing Technique: Incremental updating to minimize artifact in all leads.
  • Baseline Correction: Cubic Spline or Finite Residual Filter algorithm.
  • QRS Detection/Analysis: Based on automatic or manual lead selection.
  • ECG Output: Real-time ECG/QRS beep/TTL synchronization output.
  • Heart Rate: Automatic arrhythmia detection, documentation, and annotation.
  • Full Disclosure ECG: Beat-to-beat ECG record and event review.
  • Reanalysis: Post-test medians remeasurement from E, J, post-J point selections.
  • In-Test Reports:
    • 12SL: Interpretive resting ECG with analytical statements on morphology, rhythm, and conduction. Measurements of rate, intervals, and axes. Available before the test, in pretest and recovery. Formats include: 4 x 2.5; 4 x 2.5 + 1, 2 x 5; H2 (5 s ECG at a speed of 50 mm/s x 6) and H1 (6-lead ECG at 12.5 mm/s, Medians at 50 mm/s).
    • 3, 6, 12, or 15-Lead Report: Presents raw ECG data in various formats: 4 x 2.5 s ECG; 4 x 2.5 + 1 (2.5 seconds of raw data plus 1 continuous 10 second recording of continuous rhythm); 2.5 x 5 (5 seconds of raw data); 1 x 10 (10 seconds of raw data); H2 format (5 seconds of raw data at a speed of 50 mm/s x 6).
    • Rhythm Report: A continuous, real-time recording of raw ECG data: 3, 6, 12 leads. Leads for arrhythmia report correspond to leads on the screen (not with laser printer).
    • Arrhythmia Report: Automatic 10-second documentation of arrhythmias showing 2.5 seconds of raw data prior to ectopic beat. Leads for arrhythmia report correspond to leads on the screen.
    • Recall Report: A delayed recording of raw data 10 seconds in duration: 3, 6, 12 leads.
    • Comparative Medians Report: Baseline and current medians followed by 2.5 seconds of real-time rhythm in 12 leads. ST level and ST slope reported for each lead. Also comes in H1 Medians format of 12 medians at 50 mm/s + 6 leads (selectable) of 10-second channel of raw, real-time rhythm.
    • Linked Medians Report: 4 x 2.5 with rhythm lead. 3 channels of median beat which are linked together at the current heart rate with a fourth 10-second channel of raw, real-time rhythm.

Reviews

There are no reviews yet.

Be the first to review “CASE Value ECG System”

Your email address will not be published. Required fields are marked *

Join our newsletter and get $20 discount
for your first order

You have been successfully Subscribed! Ops! Something went wrong, please try again.

From Home to Hospital, Jexal Health Has You Covered

Company

Terms and Conditions

About Us

Copyright Notice

Payment Methods

Shipping Information

Get Help

Bulk Orders

Shipping Options

Shipping Rates

Brief Description